"Seismic gas shut-off
valves, .......... automatically stop the flow of natural gas into a home
when triggered by an earthquake."
Los Angeles Times Sunday, July 16,2000
Horizontal Valve 3/4" -
2"
Vertical Valve 3/4" - 2"
.
..........................
How
to choose the right size valve?
1. The size of the earthquake gas valve
has to match the size of your main gas pipe that enters your
home.
Before ordering a gas shutoff valve, you must measure the
gas line that enters your home.
2. Wrap a string around the main
gas line that enters your home. Mark
the exact point where the string overlaps the end.
3. Remove the string from your gas line and measure the distance
from the edge of the string to the mark you have made.
4. In the chart below in the column Pipe Circumference. The
corresponding number in the column Pipe Size is your gas line
pipe size.
5. This measurement will be within 1/8" of one of the
figures noted on the string, or in the chart below in the
column Pipe Circumference. The corresponding number in the
column Pipe Size is your gas line pipe size. Refer to this
measurement when ordering a gas shutoff valve.
Pipe Circumference
- measurement around pipe |
Pipe Size
|
3-5/16"
4-1/8"
5-1/4"
6"
7-7/16
|
3/4"
1"
1-1/4"
1-1/2"
2" |
|
Valve Specifications
Model# |
Pipe Size |
Max. Pressure |
Length |
Width |
Height |
Weight |
0.5"W.C
BTU/HR
x1000 |
1.0"W.C BTU/HR
x1000 |
Effective Pipe Length |
Cv Value |
3/4 " Gas Shutoff Valve
Specifications
|
AGV-75 Horizontal |
3/4" NPT |
5 psi |
3" |
1-1/2" |
3" |
1 lbs. |
692 |
977 |
3.4' |
18.1 |
VAGV-75 Vertical |
3/4" NPT |
10 psi |
2-1/2" |
2" |
3-3/8" |
1 lbs. |
600 |
895 |
3 |
16.4 |
1" Gas Shutoff Valve Specifications
|
AGV- 100 Horizontal |
1" NPT |
5 psi |
4" |
1-3/4" |
3-1/2" |
1.5 Lbs |
1,153 |
1,628 |
4.5' |
30.2 |
|
1" NPT |
10 psi |
2-1/2" |
2" |
3-3/8" |
1 Lbs. |
515 |
765 |
10.0' |
14.1 |
1-1/4" Gas Shutoff Valve
Specifications
|
AGV-125 Horizontal |
1-1/4" NPT |
5 psi |
4" |
2-1/3" |
4-2/3" |
3 lbs. |
1,889 |
2,677 |
6.9' |
49.6 |
VAGV-125 Vertical |
1-1/4" NPT |
10 psi |
2.5" |
2" |
3.4" |
1 lbs. |
440 |
650 |
75.0' |
12 |
VAGV-125-HF Vertical |
1-1/4" NPT |
2 psi |
4.2" |
3.3" |
5.2" |
7 lbs. |
2,400 |
3,700 |
4.0' |
56.5 |
Model# |
Pipe Size |
Max. Pressure |
Length |
Width |
Height |
Weight |
0.5"W.C BTU/HR x1000 |
1.0"W.C BTU/HR
x1000 |
Effective Pipe Length |
CV Value |
|
1-1/2" Gas Shutoff
Valve Specifications
|
AGV- 150 Horizontal |
1-1/2" NPT |
5 psi |
6" |
3" |
5-1/2" |
6 lbs. |
4,079 |
5,759 |
10.0" |
107 |
VAGV- 150 Vertical |
1-1/2" NPT |
2 psi |
4.2" |
3.3"" |
5.2" |
7 lbs. |
2,400 |
3,700 |
6.0' |
68.8 |
AGV-150-HP Horizontal |
1-1/2" NPT |
60 psi |
6" |
3" |
5-1/2" |
6 lbs. |
4.079 |
5,759 |
10.0' |
107 |
VAGV-150-HP Vertical |
1-1/2" NPT |
60 psi |
4.2" |
3.3" |
5.2" |
7 lbs. |
2,400 |
3,700 |
6.0' |
68.8 |
2" Gas Shutoff Valve Specifications
|
AGV-200 Horizontal |
2" NPT |
5 psi |
6" |
3" |
5-1/2" |
6 lbs. |
4,079 |
5,759 |
10.0' |
107 |
VAGV-200 Vertical |
2" NPT |
2 psi |
4.2" |
3.3" |
5.2" |
7 lbs. |
1,800 |
2,500 |
40.0' |
46.8 |
AGV-200-HP Horizontal |
2" NPT |
60 psi |
6" |
3" |
5-1/2" |
6 lbs. |
4,079 |
5,759 |
10.0' |
107 |
VAGV-200-HP Vertical |
2" NPT |
60 psi |
4.2" |
3.3" |
5.2" |
7 lbs. |
1,800 |
2,500 |
40.0' |
46.8 |
-
Automatically
shut off the gas during a quake.
-
Manually
can be turned ON/OFF at any time - vertical valve only.
-
Certified
by the State of California*.
-
Warranted
for 30 years by factory.
-
Friendly:
easily operated.
*Valves
Have Been Tested to ASCE 25-97, State of California 12-23-1 & ANSI
Z21.70-1981 Standards for Seismic Gas Valves.
Install
the valve with the Stabilizer Bracket and prevent false activation.
Contractors
& Professionals Quantity Quote Request Form
You could be asleep or away at work when a large
earthquake strikes your home. Earthquakes can cause gas piping to crack,
brake, leak, and create serious risk of explosion, fire, and suffocation.
The Earthquake Automatic Gas Shutoff Valve safeguards you, your loved
ones, pets, home, and belongings at all times.
The Earthquake Gas Valve automatically shuts-off
the gas flow to your property when triggered by a 5.4+ magnitude earthquake
at the valve's location.
The Little Firefighter Earthquake Automatic Gas
Shutoff Valve is tested and approved by the State
of California. It is a dual-purpose valve with a built-in
wrench that allows you to turn the gas On/Off manually as well. It has
a factory warranty for 30 years and is it installed with a stabilizer
bracket to prevent false activation.
"The seismic gas valve would automatically
shut off the gas … We know that fires can and will start after a quake."
Martinez News-Gazette. March 23, 2000.
Install
the valve with the Stabilizer Bracket and prevent false activation.
GUARANTIED!!
EARTHQUAKE GAS VALVE
SAVES LIVES
"The most common cause
of earthquake-related fires is broken gas lines"
(USGS Earthquake Hazards
Program, June 14, 2000)
Don't wait until it's too
late!
Have a gas shut off valve
installed today!
SALES
Earthquake Gas Valve Source
Berkeley, California, USA
Serving
the Bay Area since 1985
contact@GasValveDoctor.com
510. 843. 3275
Web
Master
EARTHQUAKE SAFETY gasvalve.net